Programmed intermittent epidural bolus (PIEB) is an epidural analgesia “maintenance” technique in which boluses of local anesthetic solutions are injected into the epidural space at a fixed time interval. Studies comparing PIEB to continuous epidural infusions (CEI) have shown that PIEB is associated with reduced local anesthetic consumption,1,2,3,4,5,6 longer duration of analgesia,4,7 lower incidence of breakthrough pain,8 and greater maternal satisfaction.1,4,8 There is evidence that PIEB regimens decrease motor block and instrumental deliveries.9,10 Despite the increasingly popular use of PIEB for labour analgesia, the optimum regimen of drug delivery including drug type, concentration, bolus interval, and dose using PIEB has yet to be determined.11

Our group has conducted three studies12,13,14 with different bupivacaine concentrations, volumes, and boluses intervals, aiming at establishing the optimum PIEB regimen for women during the first stage of labour. In those studies, we found that more than 40% of the women experienced sensory blocks to ice above the T6 dermatome level. While these sensory block levels were not associated with significant adverse effects in those studies, they are not required for labour analgesia and may potentially determine adverse effects.

Our first study12 was a prospective, double-blind, sequential allocation study to determine the effective interval of PIEB in 90% of women (EI90) during first stage of labour, while using a fixed bolus of 10 mL of bupivacaine 0.0625% with fentanyl 2 µg·mL−1. Our results showed that the PIEB time interval to provide effective analgesia (defined as no need for patient-controlled epidural analgesia [PCEA] or manual boluses for six hours after the loading dose or until the patient completed the first stage of labour, whichever occurred first) was approximately 40 min, which corresponds to an hourly consumption of 9.4 mg of bupivacaine.

We subsequently conducted a second study13 with the same anesthetic solution and the same PIEB interval of 40 min, aiming to determine the effective volume (dose) of local anesthetic while producing the same outcome of effective analgesia without breakthrough pain. We concluded that the volume (dose) could not be reduced without compromising the efficacy of the technique. These results validated those of our previous study.

We finally conducted a third study14 to determine the effective time interval between boluses of a more concentrated solution, bupivacaine 0.125% 5 mL plus fentanyl 2 µg·mL−1, while maintaining the same dose of local anesthetic. We observed that the EI90 for boluses of 5 mL of bupivacaine 0.125% with fentanyl 2 µg·mL−1 was approximately 35 min. Surprisingly, similar to what we had observed in our two previous studies, the incidence of women exhibiting sensory block to ice > T6 was still high, approximately 58.4%.

Based on these three previous studies, we sought to test even smaller volumes of more concentrated solutions. We therefore planned the current study using boluses of 2.5 mL of bupivacaine 0.25% with fentanyl 8 µg·mL−1, which maintained the same dose of bupivacaine and fentanyl per bolus used in our previous studies, but in a much smaller volume. We believed that a reduced bolus volume would lead to a more limited spread of the epidural mixture, which in turn could lead to better usage of the local anesthetic by reducing its hourly consumption without compromising the technique.

The objective of this study was to establish the effective PIEB interval between boluses of bupivacaine 0.25% plus fentanyl 8 µg·mL−1 that would be effective in 90% of nulliparous women requesting epidural analgesia during the first stage of labour, without breakthrough pain and no need for PCEA or physician/nurse administered bolus. Our hypothesis was that the effective interval time between PIEB boluses of 2.5 mL of 0.25% bupivacaine plus fentanyl 8 µg·mL−1 would be between 30 and 60 min.

Methods

We conducted a double-blind sequential allocation trial using a biased coin up-and-down design to determine the effective PIEB interval in 90% (EI90) of our studied population.

The study was approved by the Research Ethics Board at Mount Sinai Hospital in Toronto, Canada (REB 18-0219-A, approval date 8 November 2018) and written informed consent was obtained from all participants. The study was registered at ClinicalTrials.gov on 7 November 2018 (identifier: NCT03735771).

We recruited American Society of Anesthesiologists physical status II or III nulliparous women at a gestational age ≥ 37 weeks, with singleton fetuses in vertex presentation. We studied women in active labour (regular contractions occurring three to five minutes apart and cervical dilatation between 2 and 5 cm), requesting labour epidural analgesia during the first stage of labour (induced or augmented), with verbal numerical pain score (VNPS) greater than five at the time of epidural analgesia request (VNPS 0–10). Exclusion criteria included refusal to participate in the trial, any contraindication to epidural anesthesia, allergy or hypersensitivity to bupivacaine or fentanyl, and the use of other analgesics within the last four hours. Withdrawal criteria included unintentional dural puncture during epidural placement, and unsatisfactory response to the loading dose (defined as verbal numerical rating scale [VNRS] > 1 at 20 min after the epidural loading dose).

An infusion of 250 mL of lactated Ringer’s solution was given to the patient during epidural catheter placement. The epidural catheter was placed in the sitting position, with a midline approach, and the epidural puncture site was determined by pre-procedure spinal ultrasound assessment. After skin preparation with chlorhexidine 2% and alcohol 70%, skin was infiltrated with lidocaine 2%. A 17G Tuohy needle was inserted at the L3/4 interspace using loss of resistance to air or saline at the discretion of the anesthesiologist. A closed-end, multi-orifice, wire-reinforced epidural catheter (Arrow FlexTip plus; Arrow International Inc, Reading, PA, USA) was advanced 4–5 cm into the epidural space and was then aspirated and secured. Patients were positioned supine with left uterine displacement and 30° head-of-bed elevation.

A test dose of 3 mL of bupivacaine 0.125% + fentanyl 3.3 µg·mL−1 was given. After assessment of the test dose at three minutes, a loading dose of 12 mL of 0.125% bupivacaine with fentanyl 3.3 µg·mL−1 was administered in two aliquots of 6 mL. Patient monitoring followed institutional practice. Hypotension, defined as a decrease in blood pressure of 20% from baseline values in combination with symptoms (nausea, dizziness, vomiting or fetal bradycardia), was treated by a 250-mL rapid fluid infusion of lactated Ringer’s and/or 5 mg of intravenous ephedrine at the discretion of the anesthesiologist.

The efficacy of the epidural loading dose was assessed at 20 min after the end of the full loading dose, as per our standard practice. A successful response to the loading dose was defined as a VNRS ≤ 1 on a 0–10 scale. If no satisfactory response was obtained at 20 min, the epidural loading dose was considered to have failed for study purposes and the patient was withdrawn from the study and managed as per clinician preferences.

Those patients responding successfully to the loading dose had their PIEB regimen initiated at 60 min post loading dose. The PIEB regimen was administered with a CADD®-Solis Ambulatory Infusion System (Smith Medical, St Paul, MN, USA). The pump was programmed to deliver boluses at 250 mL·hr−1 as per our routine.

The biased coin up-and-down sequential allocation was carried out using a computer-generated list of random responses prepared by the biostatistician using Excel (Microsoft, Redmond, WA, USA). A research assistant used this list to provide the PIEB setting for the next woman in a sealed envelope. An unblinded research assistant or consultant anesthesiologist set up the epidural infusion pump. The screen of the epidural infusion pump was covered with paper to blind the participants, other investigators, and nurses.

The PIEB pump delivered boluses of 2.5 mL of 0.25% bupivacaine plus fentanyl 8 µg·mL−1 at different intervals. The PIEB interval was determined by a biased coin up-and-down sequential allocation design targeting for the effective interval that provided EI90 defined as no need for PCEA or manual boluses for 6 hours after the loading dose or until the patient completed the first stage of labour (fully dilated), whichever occurred first. The maximum interval was 60 min and the minimum interval was 30 min, therefore delivering a total volume of the epidural mixture varying from 2.5 mL (group 60 min) to 5 mL (group 30 min) per hour, which corresponds to a dose of 6.25–12.5 mg of bupivacaine per hour, respectively.

The PIEB intervals that were investigated were 60, 50, 40, and 30 min. If a patient did not respond adequately to the current PIEB interval, the case was considered to have failed for study purposes and the patient was switched to the standard PIEB regimen in practice at Mount Sinai Hospital. In that case, the PIEB interval for the subsequent study patient was decreased by ten minutes. If the patient responded to the PIEB interval, the case was considered a success, and the PIEB interval for the subsequent patient was increased by ten minutes with a probability of 1/9, otherwise it remained unchanged. In case of a successful response in group 60 or a failure in group 30, the interval for the subsequent patients was kept the same until the biased coin program indicated a decrease or increase in the interval, respectively.

The upper sensory block to ice was assessed bilaterally at the mid-clavicular lines, and the level of block was one level below that where the patient felt as cold as the forehead or cheek. Motor block was assessed according to the modified Bromage score15 (0 = able to raise extended legs; 1 = unable to raise extended legs but able to flex knees; 2 = unable to flex knees but able to flex ankle; 3 = unable to flex ankle). Pain score was assessed according to a VNRS 0–10, where: 0 = no pain and 10 = worst imaginable pain. Non-invasive blood pressure was assessed at 20 and 60 min after completing the loading dose, and then every 60 min until the end of the study.

If the PIEB interval proved insufficient during the study period, the next vaginal examination and cervix dilation was noted to ensure the patient had requested supplemental analgesia still during the first stage of labour.

The primary outcome of the study was the adequate response of the patient to the PIEB regimen, defined as no request for supplemental analgesia (PCEA bolus or clinician administered bolus) until completion of first stage of labour or until six hours following initiation of PIEB, whichever occurred first.

The secondary outcomes were the upper sensory block level to ice, motor block according to Bromage score, pain scores, hypotension, and treatment of hypotension (type of intervention).

Additional recorded data included age, weight, height, gravidity, parity, gestational age, cervical dilation, status of membranes, type of labour (spontaneous or induced), oxytocin use, consumption of bupivacaine (total amount, hourly consumption).

Statistical analysis

For a dose finding study based on biased coin up-and-down design, the distribution of data are unknown and non-independent. This prevents the development of theoretical rules to estimate the sample size for a pre-specified precision of the EI90 estimation. Simulation studies suggest that enrolling at least 20-40 patients will provide stable estimates of the target volume for most realistic cases.16 In this study, we enrolled 20 patients.

Descriptive statistical methods were used to summarize the study population. Because all the observed responses rates fell below 90%, which implied that the EI90 was not in the interval range investigated (60, 50, 40, and 30 min), the planned Dixon and Mood method and isotonic regression method (with interpolation approach)16 for estimating EI90 were not applicable. Instead, we applied the isotonic regression with extrapolation approach17,18 to estimate the EI90. To be specific, assuming Ω = {x(1) < x(2) < … < x(k)} be the k intervals investigated and p(i) be the observed rate of the primary outcome of success at interval x(i), i = 1, 2, 3, …,k. Since the observed rate of p = {p(1), p(2),…,p(k)} may not be decreased with respect to the interval (min), the implicit assumption of the study, the isotonic regression with the PAVA algorithm16 was first used to obtain a decrease adjusted rate p* = {p*(1) ≥ p*(2) ≥,…, ≥ p*(k)} based on p. Similar to the isotonic regression estimator with linear interpolation approach,19 the isotonic regression estimator of EI90 with the linear extrapolation approach here was the interval \(\hat{U}=\frac{0.9-p^{\ast}(1)}{p^{\ast}(1)-p^{\ast}(2)}(x(1)-x(2))+x(1),\) since x(1) = min (x(i):p*(i) < 0.9) when all p*(i) < 0.9. The 95% confidence interval (CI) of the EI90 was obtained by a bias-corrected percentile method16 using 2000 bootstrap replications of \(\hat{U}^{\ast}.\) Each replication was obtained by drawing a bootstrap data set with a sample size of 20 and BCUD design, assuming the true dose-response rate at each interval (min) is p*(i), i = 1, 2, 3, …,k estimated based on the original data, and then estimated \(\hat{U}^{\ast},\) the isotonic regression estimator of ED90 with linear extrapolation approach based on the bootstrap data.

Patient characteristics and secondary outcomes were described/compared between two groups, those with PIEB interval of 30 min and those with PIEB more than 30 min. All the de-identified data were analyzed by the study biostatistician.

Results

Forty-eight women were approached to participate in the study from November 2018 to June 2019. Of these, 17 declined to participate, nine were not eligible, and two were excluded because of a failed loading dose (pain prior to PIEB regimen starting). Therefore, 20 women were included in the data analysis. Patient demographics and obstetric characteristics are shown in Table 1.

Table 1 Patient characteristics and obstetric data

The patient allocation sequence and response to different PIEB interval times is shown in the Figure. The response rate for each time interval and the adjusted response rates are shown in Table 2.

Figure
figure 1

Individual responses of study participants to different PIEB time intervals. Solid circle = inadequate PIEB time interval, open circle = adequate PIEB time interval

Table 2 Observed and PAVA-adjusted response rate

From the data observed, the EI90 likely falls below 30 min, and could not be calculated using the planned methods, the Dixon and Mood method and the traditional isotonic regression with interpolation approach method. We instead used the isotonic regression with extrapolation approach to estimate the EI90 and the bootstrap method for the 95% CI. The estimated EI90 was 20 (95% CI, 5.9 to 28.8) min.

Table 3 depicts the highest upper sensory level and degree of motor block for the duration of the study. Given the small number of women assigned PIEB intervals longer than 30 min, we combined the participants in two groups only, those assigned to 30 min and those assigned to more than 30 min. The median upper sensory block level for women in the 30-min group and those assigned to more than 30 min were T6 (or T5) and T7, respectively. No participants experienced motor block. Asymptomatic hypotension that required pharmacologic treatment occurred in just one patient in the 30-min group.

Table 3 Upper sensory block level to ice and motor block

Discussion

Our results show that the estimated EI90 for our studied PIEB regimen using boluses of 2.5 mL of bupivacaine 0.25% with fentanyl 8 µg·mL−1 is 20 min. This interval is outside the interval considered in our hypothesis, which was between 30 and 60 min. This is different from our three previous studies,12,13,14 where the optimal interval was always above 30 min. Our results suggest that, contrary to our assumption, the consumption of local anesthetic with this regimen is higher than in our previous studies, and that there is no advantage in using boluses of 2.5 mL of bupivacaine 0.25% plus fentanyl 8 µg·mL−1.

The optimal PIEB regimen for epidural analgesia has yet to be determined.11 Obstetric anesthesia units adopting the PIEB technique will likely have to adapt different regimens already proposed in the literature, or develop their own, to suit the needs and expectations of their patient population.20

The spread of solutions into the epidural space is complex and multifactorial, and to date, not completely understood. Two previous studies conducted by our group13,14 used the same dose of local anesthetic in different concentrations and showed very similar results, including effective PIEB time intervals, motor block, and extent of sensory block, with a high proportion of women exhibiting a sensory block to ice above the T6 dermatome. These findings led us to look for further optimization of our PIEB regimen, given that such a wide spread of sensory analgesia is neither necessary nor desired.

Our hypothesis that a more concentrated solution and smaller volume could lead to more effective use of local anesthetic was actually in conflict with the existing evidence that more dilute solutions are in fact more effective. Nevertheless, most data available on that topic relate to CEI techniques and we wanted to test this hypothesis in the context of the PIEB technique. Previous data based on the use of CEI method21,22 speak in favour of the use of diluted local anesthetic solutions. Ginosar et al.21 compared a group of women receiving a 5 mL bolus and 5 mL·hr−1 infusion of bupivacaine 0.25% with a group of women receiving a bolus of 20 mL and 20 mL·hr−1 of diluted bupivacaine (0.0625%). The authors concluded that women who received diluted local anesthetic solutions required less supplemental analgesia, had greater maternal satisfaction, and less local anesthetic consumption. Nevertheless, as already highlighted, it is important to note that these studies21,22 evaluated a CEI with PCEA method and not a PIEB method where the physiologic concept is very different. The physiologic advantage of PIEB, as shown by the Kaynar and Shankar23 and Hogan24 studies, may be explained by the higher pressure and consequently better distribution of medication and greater longitudinal extent of circumferential spread in the epidural space. In another recent study, increased spread of epidural contrast was shown in pigs with the PIEB technique compared with CEI.25

Overall, our study suggests that the consumption of local anesthetic may in fact increase with the use of more concentrated solutions. To achieve optimal labour analgesia with the more concentrated solution (i.e., 0.25% bupivacaine), our study showed that the PIEB bolus interval time of 30 min is insufficient nearly one third of the time and a lower interval would be needed. Furthermore, using the extrapolated PIEB bolus interval of 20 min would increase the total hourly bupivacaine consumption dose to 18.75 mg, almost twice the dose of previously reported studies with less concentrated bupivacaine.12,13,14

Our results are therefore in keeping with the studies using CEI and PCEA regimens, where better results were obtained with more diluted solutions. It is important to note that our study is not a comparative one. Nevertheless, the estimated EI90 of 20 min (95% CI, 5.9 to 28.8) suggests that there would be no advantage in using concentrated solutions because of increased consumption of local anesthetic.

An interesting finding in our study that is no participant experienced motor block. This could be just a random finding. Given that we in fact increased the hourly administration of local anesthetic compared with what we used in our previous studies, it would not be surprising if a patient presented with some degree of motor block. Nevertheless, as previously observed in our other studies, the PIEB technique produces minimum motor block.

It becomes clear, from our previous and current studies, that other forms of optimization of the PIEB technique will have to be studied if one is interested in producing a less extensive and unnecessary spread of local anesthetics.

One other possible factor to be studied as a potential modifier of the epidural spread is the bolus delivery rate, given that different delivery speeds may generate different pressures in the epidural space. Current PIEB delivery devices may be programmed to deliver PIEB boluses as fast as 500 mL·hr−1. Most studies published to date have used a bolus delivery rate of 250 mL·hr−1. Lange et al.26 compared two groups of women who received a PIEB bolus either over six minutes (100 mL·hr−1) or over two minutes (300 mL·hr−1). The quality of labour analgesia and the need for supplemental analgesia were similar in both groups, suggesting that the speed of injection within the range of 100–300 mL·hr−1 does not significantly influence the spread of local anesthetic and quality of analgesia. Further studies are warranted to corroborate this finding and look closer into the effects of delivery speed on sensory block levels.

Our study has some limitations. First, the results of our study may not apply to multiparous women or nulliparous women requesting epidural analgesia in more advanced stages of labour, when dilation of the cervix is greater than 5 cm. We followed women for up to six hours after the epidural placement and did not evaluate the effectiveness of this protocol beyond six hours of labour or during second stage of labour. Second, it is important to highlight that the confirmation of our hypothesis was limited by the study design because of a restricted lower bound in time interval of 30 min. Nevertheless, we had no clinical interest in evaluating intervals smaller than 30 min, given that this would be against our rationale that the studied regimen would consume less local anesthetic. From the data observed in the study, the EI90 likely falls below 30 min and we used the isotonic regression with extrapolation approach to estimate the EI90, which was 20 min. This interval was outside the interval considered in our hypothesis. The accuracy of the estimate for linear extrapolation is dependent on the shape of the dose-response curve. Nevertheless, in this study, the true dose-response curve is unknown and therefore we estimated the accuracy of EI90, the 95% CI, using bootstrapping simulation method (2000 bootstrap simulations).

In summary, the estimated EI90 for a PIEB regimen with boluses of 2.5 mL of bupivacaine 0.25% with fentanyl 8 µg·mL−1 using the isotonic regression with extrapolation approach is 20 (95% CI, 5.9 to 28.8) min. Although not meant to be a comparative study, this result suggests that in clinical practice there is no advantage in using this regimen over those using boluses containing the same dose of bupivacaine but in concentrations of 0.0625% and 0.125%.