Indoor air quality in printing press in Kuwait

  • Original Article
  • Published:
International Journal of Environmental Science and Technology Aims and scope Submit manuscript

Abstract

The well-being of the workers in any place is the main health goal of any office; thereby, this study has focused on the printing press due to the inadequate indoor air quality. Most of the pollutants are emitted from the storage, use and disposal of chemicals and liquid/solid waste. Printing inks, toner and cartridges contain volatile organic components that have the potential to generate odors and can cause serious health risk. The press is located in a separate building, away from the main work area containing administration and laboratories. The press is responsible for various tasks, from visiting cards to conferences proceedings. Air quality inside the printing press has been assessed taking into consideration associated offices, administration, editing, printing and publications sections, and heating ventilation and air conditioning (HVAC) system performance was evaluated through continuous monitoring of temperature, humidity and carbon dioxide (CO2) levels. The assessment of the indoor air quality in printing press was completed by accurate measurements of volatile organic compounds (VOCs), CO2, temperature, humidity, ozone and particulate matters. These measured values were compared with national and international guidelines set for an acceptable indoor air quality. The results will be used for the identification of sources, which can be implemented in mitigation strategies to abate the prevalence of sick building syndrome if exists. Samples taken for 8 working hours revealed VOCs levels approached 7.72 ppm where 33.82% contribution was from halogenated compounds where predominant compound was refrigerant trichlorofloromethane (R-11) leaked from refrigeration loop of HVAC system, followed by oxygenated group 25.84% mainly consisting of methyl tertiary butyl ether common additive of gasoline emitted from light vehicles. Aliphatic group constituted 25.62% of TVOC, where predominant compound was solvent cyclohexane, and aromatic group was the least 14.72% of the TVOC consisting of toluene common thinner.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  • Al-Awadi L (2018) Assessment of indoor levels of volatile organic compounds and carbon dioxide in schools in Kuwait. J Air Waste Manag Assoc 68(1):54–72. https://doi.org/10.1080/10962247.2017.1365781

    Article  Google Scholar 

  • Al-Awadi L, Al-Rashidi M, Khan AR, Neelamani S, Aba A, Al-Dabbous A, Halaleh ME, Abdullah M, Al-Qasimi MM, Al-Saleh M, Ali AA, Al- Ballam Z (2012) Assessment of indoor organic pollutants level in selected schools. Report no. 11013, Kuwait Institute for Scientific Research, Kuwait

  • Al-Hemoud A, Al-Awadi L, Al-Rashidi M, Khan AR, Al-Khyayat A, Behbehani W (2017) Comparison of indoor air quality in schools: urban versus industrial ‘oil and gas’ zones in Kuwait. Build Environ 122:50–60

    Article  Google Scholar 

  • Al-Khulaifi NM, Al-Mudhaf HF, Alenezi R, Abu-Shady ASI, Selim MI (2014) Seasonal and temporal variations in volatile organic compounds in indoor and outdoor air in Al-Jahra City, Kuwait. J Environ Protoc 5:310–326. https://doi.org/10.4236/jep.2014.54034

    Article  CAS  Google Scholar 

  • Al-Mudhaf HF, Abu-Shady ASI, Al-Khulaifi NM (2013) Indoor and outdoor volatile organic compounds at office buildings in Kuwait. Air Soil Water Res 6:53–72

    Article  CAS  Google Scholar 

  • Barn P (1997) Indoor air quality assessments: “volatile organic compounds”, total volatile organic compounds (TVOC) in indoor air quality investigations, report 19. Brussels 1997 Contract no.: EUR 17675 EN. Available from: http://ihcp.jrc.ec.europa.eu/our_activities/public-health/indoor_air_quality/eca/eca_report_19

  • Black SC, Townsend YE (1996) National emission standards for hazardous air pollutants submittal-1995 (No. DOE/NV/11718–032). Bechtel Nevada Corp., Las Vegas, NV

  • Bo M, Salizzoni P, Clerico M, Buccolieri R (2017) Assessment of indoor–outdoor particulate matter air pollution: a review. Atmosphere 8(136):1–18. https://doi.org/10.3390/atmos8080136

    Article  CAS  Google Scholar 

  • Butler DA, Madhavan G, Alper J (2016) Health risks of indoor exposure to particulate matter: workshop summary. National Academies of Sciences, Engineering, and Medicine, National Academies Press. 500 Fifth Street, NW, Keck 360, Washington, DC 20001; 800-624-6242 or 202-334-3313. www.nap.edu

  • Cheong KW, Chong KY (2001) Development and application of an indoor air quality audit to an air-conditioned building in Singapore. Build Environ 36:181–188

    Article  Google Scholar 

  • Davis ME, Blicharz AP, Hart JE, Laden F, Garshick E, Smith TJ (2007) Occupational exposure to volatile organic compounds and aldehydes in the U.S. trucking industry. Environ Sci Technol 41(20):7152–7158. https://doi.org/10.1021/es071041z

    Article  CAS  Google Scholar 

  • Floyd EL, Wang J, Regens JL (2017) Fume emissions from a low-cost 3-D printer with various filaments. J Occup Environ Hyg 14(7):523–533

    Article  CAS  Google Scholar 

  • Guide to Occupational Exposure Values (2017) Compiled by American Conference of Governmental Industrial Hygienists (ACGIH), 1330 Kemper Meadow Drive Cincinnatgi, Ohio 45240-4148, http://www.acgih.org

  • Health Safety Executive (2017) Printing process chemicals and health effects, sighted on 21st Nov 2017. http://www.hse.gov.uk/aboutus/index.htm

  • Hong Kong Labour Department (2002) Code of practice on control of air impurities (chemical substances) in the work place

  • Hu D, Yang Y, Zhang W, Peng X, Wei Q, Yuan J, Zhu Z (2016) Health risk assessment for inhalation exposure to methyl tertiary butyl ether at petrol stations in southern China. Int J Environ Res Public Health 13(2):204–212. https://doi.org/10.3390/ijerph13020204

    Article  CAS  Google Scholar 

  • Jones AP (1999) Indoor air quality and health. Atmos Environ 33(28):4535–4564

    Article  CAS  Google Scholar 

  • Kataoka H, Ohashi Y, Mamiya T, Nami K, Saito, K, Ohcho K, Takigawa T (2012) Indoor air monitoring of volatile organic compounds and evaluation of their emission from various building materials and common products by gas chromatography-mass spectrometry, advanced gas chromatography—progress in agricultural, biomedical and industrial applications. Dr. Mustafa Ali Mohd (ed). ISBN: 978-953-51-0298-4, InTech, Available from: http://www.intechopen.com/books/advanced-gaschromatography-progress-in-agricultural-biomedical-and-industrial-applications/indoor-air-monitoring-ofvolatile-organic-compounds-and-evaluation-of-their-emission-from-various-bu

  • Kiurski JS, Marić BB, Aksentijević SM, Oros IB, Kecić VS, Kovacˇević IM (2013) Indoor air quality investigation from screen printing industry. Renew Sustain Energy Rev 28:224–231

    Article  CAS  Google Scholar 

  • Kiurski JS, Marić BB, Oros IB, Kecić VS (2017) The ecodesign practice in Serbian printing industry. J Clean Prod 149:1200–1209

    Article  Google Scholar 

  • Le Roux T (2016) Governing the toxics and the pollutants. France–Great Britain 1750–1850. Endeavour 40(2):70–81

    Article  Google Scholar 

  • Leung MKH, Liu C-H, Chan AHS (2005) Occupational exposure to volatile organic compounds and mitigation by push–pull local exhaust ventilation in printing plants. J Occup Health 47:540–547

    Article  CAS  Google Scholar 

  • Molhave L, Clausen G, Berglund B, Ceaurriz JD, Kettrup A, Lindvall T, Maroni M, Pickering AC, Risse U, Rothweiler H, Seifert B (1997) Total volatile organic compounds (TVOC) in indoor air quality investigations. Indoor Air 7(4):225–240

    Article  CAS  Google Scholar 

  • Norback D, Wieslander G, Edling C (1995) Occupational exposure to volatile organic compounds and other air pollutants from indoor application of water based paints. Ann Occup Hyg 39(6):783–794

    Article  CAS  Google Scholar 

  • Ramadan A (2017) Assessment of spatial variation of ambient volatile organic compound levels at a power station in Kuwait. J Air Waste Manag Assoc 67(11):1170–1179. https://doi.org/10.1080/10962247.2016.1241196

    Article  CAS  Google Scholar 

  • Saraga D, Patraki S, Papadopoulos A, Vasilakos Ch, Maggos T (2011) Studying the indoor air quality in three non-residential environments of different use: a museum, a printery industry and an office. Build Environ 46:2333–2341

    Article  Google Scholar 

  • Sexton K, Adgate JL, Ramachandran G, Pratt GC, Mongin SJ, Stock TH, Morandi MT (2004) Comparison of personnel indoor and outdoor exposures of hazardous air pollutants in three urban communities. Environ Sci Technol 38:423–430

    Article  CAS  Google Scholar 

  • Tuomi T, Engström B, Niemelä R, Svinhufvud J, Reijula K (2000) Emission of ozone and organic volatiles from a selection of laser printers and photocopiers. Appl Occup Environ Hyg 15(8):629–634

    Article  CAS  Google Scholar 

  • US EPA (1996) Work assignment no III, emission factor documentation for AP-42 Sect. 12.20

  • WHO Air Quality Guidelines Global Update (2005) WHOLIS no. E87950, report on a working group meeting Bonn, Germany 18–20 October 2005, sighted on 22nd Jan. 2018. http://www.euro.who.int/__data/assets/pdf_file/0008/147851/E87950.pdf

  • Wadden RA, Scheff PA, Keil CB, Franks JE, Conroy LM (1995) Determination of VOC emission rates and compositions for offset printing. J Air Waste Manag Assoc 45(7):547–555

    Article  CAS  Google Scholar 

Download references

Acknowledgement

Authors would like to acknowledge the service division in the governmental research institute for providing access to printing press facilities and KISR team for conducting thorough research about indoor air quality in the printing press.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to L. Al-Awadi.

Additional information

Editorial responsibility: Mohamed Fathy Yassin.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Al-Awadi, L., Al-Rashidi, M., Pereira, B. et al. Indoor air quality in printing press in Kuwait. Int. J. Environ. Sci. Technol. 16, 2643–2656 (2019). https://doi.org/10.1007/s13762-018-1800-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13762-018-1800-1

Keywords

Navigation